RFID Verify
Note
UIDs are read from left to right using big-endian format.
Note
Valid lengths of UIDs are 8, 14, and 20 characters. If you have shorter UIDs, you need to zero-pad them on the left.
Note
UIDs need to be all upper case.
Request
"rfid-verify"
identifies this call as an rfid verify call.
Fields
- rfid
The RFID (UID) to verify (string).
Important
An RFID must have a length of 8, 14 or 20 characters. If necessary, the RFID must be zero-padded on the left.
It should be read from left to right using big-endian format.
All characters must be upper-case.
Response
HTTP Status code
- 200 OK
The request was processed successfully.
Result code
- 0
Success
- 191
EVCO ID not found
- 192
EVCO ID locked
- 193
EVCO ID has no valid payment method
Examples
Request:
{
"rfid-verify": {
"rfid": "12345678ABCDEF"
}
}
Response:
{
"result": {
"code": 0,
"message": "Success."
}
}